{"id":11908,"date":"2025-07-02T13:49:28","date_gmt":"2025-07-02T11:49:28","guid":{"rendered":"https:\/\/cidladev.mh370.cz\/sin-categoria\/vse-dulezite-o-co2\/"},"modified":"2026-03-06T20:55:36","modified_gmt":"2026-03-06T19:55:36","slug":"todo-lo-importante-sobre-co2","status":"publish","type":"post","link":"https:\/\/www.protronix-sensors.com\/es\/articulos\/todo-lo-importante-sobre-co2\/","title":{"rendered":"Todo lo importante sobre el CO2"},"content":{"rendered":"<h3 class=\"p1\" style=\"text-align: left;\">Todo lo importante sobre el CO<sub>2<\/sub><\/h3>\n<p>\\n<\/p>\n<div class=\"gdc_row\">\n<div class=\"gdc_column gdc_chalf\">\n<div class=\"gdc_inner\">\n\\n<br \/>\n\\n<strong>\u00bfQu\u00e9 es el CO<sub>2<\/sub> o&nbsp;di\u00f3xido de carbono?<\/strong><br \/>\n\\n<br \/>\n\\nEl CO<sub>2<\/sub> es un gas incoloro, ins\u00edpido y sin olor, m\u00e1s pesado que el aire y en baja concentraci\u00f3n es una parte natural del aire circundante. A&nbsp;trav\u00e9s del proceso de respiraci\u00f3n, parte del ox\u00edgeno contenido en el aire inhalado se convierte en di\u00f3xido de carbono. Entre otras fuentes t\u00edpicas se encuentra generalmente la combusti\u00f3n, por ejemplo, una estufa de gas es una fuente significativa de CO<sub>2<\/sub><span class=\"s1\"> <\/span>en los hogares.<br \/>\n\\n<\/p>\n<p class=\"p1\"><strong>La cantidad de CO<span class=\"s1\">2<\/span> en el aire se expresa en unidades de \u00abppm\u00bb.<\/strong><\/p>\n<p>\\n<\/p>\n<p class=\"p1\">Las unidades \u00abppm\u00bb provienen del ingl\u00e9s \u00abParts Per Million ~ partes por mill\u00f3n\u00bb. 1 ppm es, por lo tanto, una parte en un mill\u00f3n = 1 millon\u00e9sima. Por ejemplo, una concentraci\u00f3n de 1,000 ppm de CO<sub>2<\/sub> en el aire significa que en cada mill\u00f3n de mol\u00e9culas de aire hay 1,000 mol\u00e9culas de CO<sub>2<\/sub> y 999,000 mol\u00e9culas de otros gases.<\/p>\n<p>\\n<\/p>\n<p class=\"p1\"><strong>El aire exterior actualmente contiene aproximadamente 420 ppm de CO<sub>2<\/sub>.<\/strong><\/p>\n<p>\\n<\/p>\n<p class=\"p1\"><\/div>\n<\/div>\n<p>\\n<\/p>\n<div class=\"gdc_column gdc_chalf\">\n<div class=\"gdc_inner\">\n<p>\\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-11223 \" src=\"https:\/\/www.cidla.cz\/wp-content\/uploads\/2025\/07\/kolaz-zdroje-co2.jpg\" alt=\"Collage que muestra fuentes t\u00edpicas de CO2; Personas, emisiones de autom\u00f3viles, estufa de gas.\" width=\"491\" height=\"347\" srcset=\"https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/kolaz-zdroje-co2.jpg 1600w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/kolaz-zdroje-co2-300x212.jpg 300w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/kolaz-zdroje-co2-768x543.jpg 768w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/kolaz-zdroje-co2-1536x1086.jpg 1536w\" sizes=\"auto, (max-width: 491px) 100vw, 491px\" \/><\/div>\n<\/div>\n<p>\\n<\/p><\/div>\n<p>\\n<br \/>\n\\n<\/p>\n<div class=\"gdc_row\">\n<div class=\"gdc_column gdc_chalf\">\n<div class=\"gdc_inner\">\n\\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10617 \" src=\"https:\/\/www.cidla.cz\/wp-content\/uploads\/2019\/05\/26_clanek-e1755000204755-300x201.webp\" alt=\"Fatiga causada por CO2\" width=\"461\" height=\"309\" srcset=\"https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2019\/05\/26_clanek-e1755000204755-300x201.webp 300w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2019\/05\/26_clanek-e1755000204755-768x515.webp 768w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2019\/05\/26_clanek-e1755000204755.webp 800w\" sizes=\"auto, (max-width: 461px) 100vw, 461px\" \/><\/div>\n<\/div>\n<p>\\n<\/p>\n<div class=\"gdc_column gdc_chalf\">\n<div class=\"gdc_inner\">\n\\n<\/p>\n<p class=\"p1\">Hist\u00f3ricamente, en el siglo XIX, el m\u00e9dico b\u00e1varo <strong>Max Josef von Pettenkofer<\/strong>, basado en el estudio del efecto negativo del aire exhalado que contiene olores y aromas liberados por la respiraci\u00f3n y la piel, propuso utilizar la concentraci\u00f3n de CO<sub>2<\/sub> como un indicador adecuado para evaluar la ventilaci\u00f3n. Y propuso una concentraci\u00f3n l\u00edmite de 1,000 ppm como indicador de ventilaci\u00f3n insuficiente. Este criterio comenz\u00f3 a&nbsp;utilizarse gradualmente m\u00e1s para evaluar la intensidad de la ventilaci\u00f3n y su control.<\/p>\n<p>\\n<\/p>\n<p class=\"p1\">Posteriormente, este criterio comenz\u00f3 a&nbsp;implementarse cada vez m\u00e1s en la pr\u00e1ctica y se increment\u00f3 el l\u00edmite en el rango de 1,000 \u2013 1,500 ppm. La ventilaci\u00f3n controlada, basada en el monitoreo de la concentraci\u00f3n actual de CO<sub>2<\/sub>, asegura un intercambio de aire controlado y, gracias a&nbsp;ello, se mantiene tanto una baja concentraci\u00f3n de CO<sub>2<\/sub> como se reduce autom\u00e1ticamente la concentraci\u00f3n de otros contaminantes.<\/p>\n<p>\\n<\/p>\n<p class=\"p1\">Son diferentes tipos de compuestos org\u00e1nicos vol\u00e1tiles que se liberan t\u00edpicamente debido a&nbsp;la actividad metab\u00f3lica del organismo humano a&nbsp;trav\u00e9s de la respiraci\u00f3n, el sudor, la transpiraci\u00f3n de la piel, etc. Adem\u00e1s, esta ventilaci\u00f3n controlada tambi\u00e9n contribuye al ahorro de energ\u00eda, ya que evita la ventilaci\u00f3n incontrolada.<\/p>\n<p>\\n<\/p>\n<p class=\"p1\"><\/div>\n<\/div>\n<p>\\n<\/p><\/div>\n<\/p>\n<p>\\n<br \/>\n\\n<\/p>\n<h3>Anatom\u00eda del aire exhalado<\/h3>\n<p>\\n<\/p>\n<div class=\"gdc_row\">\n<div class=\"gdc_column gdc_chalf\">\n<div class=\"gdc_inner\">\n\\n<br \/>\n\\n<strong>\u00bfPor qu\u00e9 monitorear el CO<sub>2<\/sub>?<\/strong><br \/>\n\\n<\/p>\n<p class=\"p1\">El CO<sub>2<\/sub> es un excelente indicador de cu\u00e1n exhalado est\u00e1 actualmente el aire. <strong>La raz\u00f3n principal es que si una persona inhala aire exterior, el aire exhalado contiene (adem\u00e1s de varios olores y aromas) hasta aproximadamente 100 veces mayor concentraci\u00f3n de CO<span class=\"s1\"><sub>2<\/sub><\/span>.<\/strong><\/p>\n<p>\\n<\/p>\n<p class=\"p1\">Por lo tanto, si las personas se encuentran en espacios interiores donde no se garantiza una ventilaci\u00f3n adecuada, la concentraci\u00f3n de di\u00f3xido de carbono aumenta bastante r\u00e1pido.<\/p>\n<p>\\n<\/p>\n<p class=\"p1\">La concentraci\u00f3n de di\u00f3xido de carbono en los edificios est\u00e1 estrechamente relacionada con la cantidad de aire fresco que se introduce en el edificio. Por lo tanto, tiene una muy buena capacidad predictiva sobre cu\u00e1n exhalado est\u00e1 el aire en un espacio determinado y cu\u00e1nta ventilaci\u00f3n se est\u00e1 realizando actualmente.<\/p>\n<p>\\n<\/p>\n<p class=\"p1\"><\/div>\n<\/div>\n<p>\\n<\/p>\n<div class=\"gdc_column gdc_chalf\">\n<div class=\"gdc_inner\">\n\\n<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-11198 aligncenter\" src=\"https:\/\/www.cidla.cz\/wp-content\/uploads\/2025\/07\/Graf-CO2.png\" alt=\"\" width=\"751\" height=\"597\" srcset=\"https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/Graf-CO2.png 2130w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/Graf-CO2-300x238.png 300w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/Graf-CO2-1600x1272.png 1600w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/Graf-CO2-768x610.png 768w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/Graf-CO2-1536x1221.png 1536w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/07\/Graf-CO2-2048x1628.png 2048w\" sizes=\"auto, (max-width: 751px) 100vw, 751px\" \/><\/div>\n<\/div>\n<p>\\n<\/p><\/div>\n<\/p>\n<p>\\n<br \/>\n\\n<\/p>\n<h3 class=\"p1\" style=\"text-align: left;\">Propagaci\u00f3n del CO<sub>2 <\/sub>en el espacio<\/h3>\n<p>\\n<\/p>\n<p class=\"p2\">El CO<span class=\"s2\"><span class=\"s1\"><sub>2<\/sub><\/span><\/span> es m\u00e1s pesado que el aire, la densidad del CO<span class=\"s2\"><span class=\"s1\"><sub>2<\/sub><\/span><\/span> es 1.839 kg\/m<span class=\"s2\">3 <\/span>a&nbsp;20&nbsp;\u00b0C y presi\u00f3n de 1,013 hPa, mientras que la densidad del aire es 1.205 kg\/m<span class=\"s2\">3<\/span>. Sin embargo, en un espacio normal, debido al movimiento t\u00e9rmico (corrientes de aire ascendentes y descendentes), el movimiento de las personas presentes y la ventilaci\u00f3n, hay una mezcla constante con el aire circundante y el ambiente interior es en gran medida relativamente homog\u00e9neo.<\/p>\n<p>\\n<\/p>\n<p class=\"p2\">La estratificaci\u00f3n, donde el CO<span class=\"s2\"><span class=\"s1\"><sub>2<\/sub><\/span><\/span> m\u00e1s pesado desciende al suelo, ocurre principalmente en s\u00f3tanos o&nbsp;pozos o&nbsp;cuevas, donde hay un movimiento m\u00ednimo de aire.<\/p>\n<p>\\n<br \/>\n\\n<\/p>\n<h3 class=\"p1\" style=\"text-align: left;\">Sensores de CO<sub>2<\/sub><\/h3>\n<p>\\n<\/p>\n<table style=\"width: 91.093378%; height: 401px;\">\n\\n<\/p>\n<tbody>\n\\n<\/p>\n<tr style=\"height: 377px;\">\n\\n<\/p>\n<td style=\"width: 48.46056%; height: 377px;\"><a href=\"https:\/\/www.cidla.cz\/produkty\/cidla-co2\/cidlo-nl-eco-co2\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11181 size-medium\" src=\"https:\/\/www.cidla.cz\/wp-content\/uploads\/2025\/06\/NL-ECO-300x272.png\" alt=\"\" width=\"300\" height=\"272\" srcset=\"https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/06\/NL-ECO-300x272.png 300w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/06\/NL-ECO.png 575w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/td>\n<p>\\n<\/p>\n<td style=\"width: 121.768448%; height: 377px;\">\n\\n<\/p>\n<h3 class=\"p2\" style=\"text-align: left;\"><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.cidla.cz\/produkty\/cidla-co2\/cidlo-nl-eco-co2\/\" target=\"_blank\" rel=\"noopener\"><strong>NL-ECO-CO2<\/strong><\/a><\/span><\/h3>\n<p>\\n<\/p>\n<p class=\"p3\" style=\"text-align: left;\">Rango opcional \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 400 \u2013 1,000 \/ 2,000 \/ 5,000 ppm<\/p>\n<p>\\n<\/p>\n<p class=\"p3\" style=\"text-align: left;\">Salida anal\u00f3gica \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a00 \u2013 10 V<\/p>\n<p>\\n<\/p>\n<p class=\"p3\" style=\"text-align: left;\">Contacto de rel\u00e9 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 250 V&nbsp;AC \/ 30 V&nbsp;DC<\/p>\n<p>\\n<\/p>\n<p class=\"p3\" style=\"text-align: left;\">Alimentaci\u00f3n \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 12 \u2013 24 V&nbsp;AC \/ DC o&nbsp;230 V&nbsp;AC<\/p>\n<p>\\n<br \/>\n\\n<\/p>\n<ul>\n\\n \\t<\/p>\n<li style=\"text-align: left;\">Sensor de espacio <span class=\"s2\">CO<\/span><span class=\"s3\">2<\/span><\/li>\n<p>\\n \\t<\/p>\n<li class=\"p3\" style=\"text-align: left;\">Modo nocturno \u2014 apagado autom\u00e1tico de LED por la noche<br \/>\n\\nOpcionalmente:<\/li>\n<p>\\n<\/ul>\n<p>\\n<\/p>\n<ul>\n\\n \\t<\/p>\n<li class=\"p3\" style=\"text-align: left;\">Alarma sonora<\/li>\n<p>\\n \\t<\/p>\n<li class=\"p3\" style=\"text-align: left;\">Bot\u00f3n capacitativo de ventilaci\u00f3n por impacto<\/li>\n<p>\\n<\/ul>\n<p>\\n<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr style=\"height: 24px;\">\n\\n<\/p>\n<td style=\"width: 48.46056%; height: 24px;\"><a href=\"https:\/\/www.cidla.cz\/produkty\/cidla-co2\/cidlo-nl-eco-co2-d\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11180 \" src=\"https:\/\/www.cidla.cz\/wp-content\/uploads\/2025\/06\/NL-ECO-D-300x272.png\" alt=\"\" width=\"343\" height=\"311\" srcset=\"https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/06\/NL-ECO-D-300x272.png 300w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/06\/NL-ECO-D.png 575w\" sizes=\"auto, (max-width: 343px) 100vw, 343px\" \/><\/a><\/td>\n<p>\\n<\/p>\n<td style=\"width: 121.768448%; height: 24px;\">\n\\n<\/p>\n<h3 style=\"text-align: left;\"><a href=\"https:\/\/www.cidla.cz\/produkty\/cidla-co2\/cidlo-nl-eco-co2-d\/\" target=\"_blank\" rel=\"noopener\">NL-ECO-CO2-D<\/a><\/h3>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Rango opcional \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 400 \u2013 2,000 \/ 400 \u2013 5,000 ppm<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Salida anal\u00f3gica. \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 0 \u2013 10 V<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Contacto de rel\u00e9 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0250 V&nbsp;AC \/ 30 V&nbsp;DC<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Alimentaci\u00f3n. \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a012 \u2013 24 V&nbsp;AC \/ DC<\/p>\n<p>\\n<br \/>\n\\n<\/p>\n<ul>\n\\n \\t<\/p>\n<li class=\"p1\" style=\"text-align: left;\"><span class=\"s1\">Sensor <\/span><span class=\"s2\">CO<\/span><span class=\"s3\">2<\/span><span class=\"s1\"> para conducto de ventilaci\u00f3n<\/span><\/li>\n<p>\\n<\/ul>\n<p>\\n<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr style=\"height: 377px;\">\n\\n<\/p>\n<td style=\"width: 48.46056%; height: 377px;\"><a href=\"https:\/\/www.cidla.cz\/produkty\/cidla-co2\/cidlo-ads-co2-24\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11177 size-medium\" src=\"https:\/\/www.cidla.cz\/wp-content\/uploads\/2025\/06\/ADS-300x272.png\" alt=\"\" width=\"300\" height=\"272\" srcset=\"https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/06\/ADS-300x272.png 300w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/06\/ADS.png 575w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/td>\n<p>\\n<\/p>\n<td style=\"width: 121.768448%; height: 377px;\">\n\\n<\/p>\n<h3 class=\"p2\" style=\"text-align: left;\"><a href=\"https:\/\/www.cidla.cz\/produkty\/cidla-co2\/cidlo-ads-co2-24\/\" target=\"_blank\" rel=\"noopener\"><strong>ADS-CO2-24<\/strong><\/a><\/h3>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Rango \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 400 \u2013 2,000 ppm<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Salida anal\u00f3gica \u00a0 \u00a0 \u00a0 \u00a0 \u00a00 \u2013 10 V, 0 \/ 4 \u2013 20 mA<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Contacto de rel\u00e9 \u00a0 \u00a0 \u00a0250 V&nbsp;AC \/ 30 V&nbsp;DC<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Alimentaci\u00f3n \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a024 V&nbsp;AC \/ DC<\/p>\n<p>\\n<br \/>\n\\n<\/p>\n<ul>\n\\n \\t<\/p>\n<li class=\"p1\" style=\"text-align: left;\">Sensor de espacio <span class=\"s1\">CO<\/span><span class=\"s2\">2<\/span><\/li>\n<p>\\n<\/ul>\n<p>\\n<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr style=\"height: 24px;\">\n\\n<\/p>\n<td style=\"width: 48.46056%; height: 24px;\"><a href=\"https:\/\/www.cidla.cz\/produkty\/cidla-co2\/cidlo-do-zastavby-cl-co2\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11178 size-medium\" src=\"https:\/\/www.cidla.cz\/wp-content\/uploads\/2025\/06\/CL-300x272.png\" alt=\"\" width=\"300\" height=\"272\" srcset=\"https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/06\/CL-300x272.png 300w, https:\/\/www.protronix-sensors.com\/wp-content\/uploads\/2025\/06\/CL.png 575w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/td>\n<p>\\n<\/p>\n<td style=\"width: 121.768448%; height: 24px;\">\n\\n<\/p>\n<h3 style=\"text-align: left;\"><a href=\"https:\/\/www.cidla.cz\/produkty\/cidla-co2\/cidlo-do-zastavby-cl-co2\/\" target=\"_blank\" rel=\"noopener\">CL-CO2<\/a><\/h3>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Rango opcional \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 400 \u2013 2,000 \/ 400 \u2013 5,000 ppm<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Salida anal\u00f3gica \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a00 \u2013 10 V<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Bus RS485 \/ Modbus<\/p>\n<p>\\n<\/p>\n<p class=\"p1\" style=\"text-align: left;\">Alimentaci\u00f3n \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a012 \u2013 24 V&nbsp;AC \/ DC<\/p>\n<p>\\n<br \/>\n\\n<\/p>\n<ul>\n\\n \\t<\/p>\n<li class=\"p1\" style=\"text-align: left;\"><span class=\"s1\">Sensor empotrado <\/span><span class=\"s2\">CO<\/span><span class=\"s3\">2 <\/span><span class=\"s1\">en caja de instalaci\u00f3n<\/span><\/li>\n<p>\\n \\t<\/p>\n<li class=\"p1\" style=\"text-align: left;\"><strong><span class=\"s1\">Cubierta final con tap\u00f3n original<\/span><\/strong><\/li>\n<p>\\n<\/ul>\n<p>\\n<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/tbody>\n<p>\\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Todo lo importante sobre el CO2 \\n \\n \\n \\n \\n Anatom\u00eda del aire exhalado \\n \\n \\n Propagaci\u00f3n del CO2 en el espacio \\n El CO2 es m\u00e1s pesado que el aire, la densidad del CO2 es 1.839 kg\/m3 a&nbsp;20&nbsp;\u00b0C y presi\u00f3n de 1,013 hPa, mientras que la densidad del aire es 1.205 kg\/m3&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":11916,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55,151],"tags":[],"class_list":["post-11908","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos","category-eventos"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/posts\/11908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/comments?post=11908"}],"version-history":[{"count":1,"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/posts\/11908\/revisions"}],"predecessor-version":[{"id":13790,"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/posts\/11908\/revisions\/13790"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/media\/11916"}],"wp:attachment":[{"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/media?parent=11908"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/categories?post=11908"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.protronix-sensors.com\/es\/wp-json\/wp\/v2\/tags?post=11908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}